ZY Cyclone separators - Product variants

For a larger view, please mouseover the image.
ZY1

Characteristic
- Cyclone separator in stainless steel cast without replaceable insert
- Design parameters: 76 bar(g) at 150 °C / 71 bar(g) at 200 °C
- Process connections: ½‘‘ NPT thread
- Very cost efficient
- Maximum particle size: 1 mm
For a larger view, please mouseover the image.
ZY2

Characteristic
- Cyclone separator with replaceable ceramic insert
- Design parameters: 100 bar(g) at 200 °C
- Process connections: ½‘‘NPT thread, Flange ½‘‘ for 600 / 1500 / 2500 lbs
- Low space requirements because of compact design and integrated flanges
- Long lifetime due to wear resistant ceramic insert
- Maximum particle size: 1 mm
For a larger view, please mouseover the image.
ZY3

Characteristic
- Higher flow rate than ZY2
- Cyclone separator with replaceable ceramic insert
- Design parameters: 100 bar(g) at 200 °C
- Process connections: ¾‘‘ NPT thread, Flange ¾ ‘‘ for 600 / 1500 / 2500 lbs
- Low space requirements because of compact design and integrated flanges
- Long lifetime due to wear resistant ceramic insert
- Maximum particle size: 2 mm


Circulation in accordance with API 682 / ISO 21049: Plan 31, API Plan 41
Standard versions

Type Insert Flow rate
max. allowable pressure Process
connections
Housing/
cover
O-Ring
ZY1 5 … 15 l/min
1.3 … 4 gpm
76 bar(g) @ 150 °C
(1100 psig @ 300 °F)
½‘‘ NPT thread CF8M / 1.4408 FKM
ZY2 Ceramic 5 … 15 l/min
1.3 … 4 gpm
100 bar(g) @ 200 °C
(1450 psig @ 390 °F)
½‘‘ NPT thread
Flange ½‘‘ 600 lbs
316L / 1.4404 FFKM
ZY3 Ceramic 30 … 70 l/min
8 … 18.5 gpm
100 bar(g) @ 200 °C
(1450 psig @ 390 °F)
¾‘‘ NPT thread
Flange ¾‘‘ 600 lbs
316L / 1.4404 FFKM

Other possible designs:

Type max. allowable pressure* Process connections* Housing/cover O-Ring
ZY1 FFKM,
EPDM
ZY2 200 bar(g) @ 200 °C
(2900 psig @ 390 °F)
Flange ½‘‘ 1500/
2500 lbs
318LN / 1.4462
UNSS32760 / 1.4501
FKM,
EPDM
ZY3 200 bar(g) @ 200 °C
(2900 psig @ 390 °F)
Flange ¾‘‘ 1500 /
2500 lbs
318LN / 1.4462
UNSS32760 / 1.4501
FKM,
EPDM

*Higher pressure / temperatures and other designs on request.



{u'ApplicationOperationalArea': '', u'IDProductItem': '1159', u'IDProductInfo': '2360', u'StructureLevel': 'Group', u'SealCodes': '', u'OperatingLimits': '', u'Note': '', u'TechnicalData': 'The ZY range (shown: ZY1) is available in three basic versions:<br/>\n</br>\n<b>ZY1</b>:\n<ul class="SGBulletList">\n<li>Cyclone separator in stainless steel cast without replaceable insert</li>\n<b>ZY2</b>:\n<ul class="SGBulletList">\n<li>Cyclone separator with replaceable ceramic insert</li>\n<b>ZY3</b>\n<ul class="SGBulletList">\n<li>Higher flow rate as ZY2</li>\n</ul>', u'Online': 'true', u'DrawingProduct': '', u'Level2ProductGroup_Group': 'None', u'ProductDomain': 'None', u'IDProductItemH': '1157', u'Description': '', u'TorqueTransmission': '', u'GenerateMeasurement': '', u'InquiryClass': '', u'MailRecipient': '', u'Level1ProductRange_Range': '', u'DrawingInstallation': 'None', u'Level3ProductSection_Section': '', u'IDInquiryClass': '', u'RecipientPhone': '', u'SupplySystem': '', u'SeatAlternative': '', u'Language': 'en-US', u'MediaResistance': '', u'DescriptionHeader': '', u'RecipientName': '', u'Position': '1', u'ApplicationBranch': '<ul class="SGBulletList">\n<li>Water and waste water technology</li>\n<li>Petrochemical industry</li>\n<li>Chemical industry</li>\n<li>Oil and gas industry</li>\n<li>Refining technology</li>\n</ul>', u'DimensionHeader': '', u'Dimension': '', u'UID': '43c2a308e2094176b20e92771e01a684', u'TechnicalDiagram': 'None', u'Features': 'Cyclone separators of the ZY range are used to clean mainly aqueous liquids containing dirt and solids (e.g. in circulation systems of sewage, sludge or pipeline pumps). The best possible filtration efficiency is achieved when the specific weight of the solids is much higher than that of the carrier liquid (recommended by API 682 4th edition: at least double), and when the differential pressure is as large as possible within the permissible pressure range (min. 1.7 bar in accordance with API 682). The viscosity of the medium is also a factor that needs to be taken into account.', u'Certification': '', u'DescriptionText': '', u'ApplicationMedia': '', u'MaterialCombination': '', u'ProductVariant': 'None', u'ProductName': 'ZY', u'ArticleNumber': '', u'SupplyForm': '', u'IDSealDrawing': '', u'PageHeader': 'ZY Cyclone separators', u'DescriptionList': '<ul class="SGBulletList">\n<li>Contaminations are automatically conveyed to the suction nozzle of the pump: maintenance-free mode of operation for guaranteed reliability</li>\n<li>High filtration efficiency</li>\n<li>Wide range of products for the optimum solution for every application</li>\n<li>ZY2 and ZY3: for operating pressures of up to 200 bar</li>\n<li>ZY2 and ZY3: optional in block-type design with integrated flange connections: low space requirements because of compact design</li>\n</ul>'}