TS5000

TS5000 For a larger view, please mouseover the image.
For a larger view, please mouseover the image.
Item Description
1 Buffer/barrier fluid IN (G1/2“)
2 Buffer/barrier fluid OUT (G1/2“)
3 Cooling water IN (G1/2“)
4 Cooling water OUT (G1/2“)
5 Filling connection with plug (G1/2“)
6 Pressure gas connection (G1/2“)
7 Connection for level switch or level indicator (G2“)
8 Connection for refill unit (G1/8“)
9 Universal connection (G1/2“ for safety valve, flare, etc.)
10 Bracket for refill unit
11 Sight-glass
With the gap-free executed EagleBurgmann TS5000 thermosiphon system it is possible to supply buffer/barrier fluid to double and tandem mechanical seals for a broad range of applications. This range is designed as a flanged version with a sight-glass for level monitoring and with cooling coil. TS vessels are equipped as standard with all the necessary system connections and brackets.

Circulation based on API 682 / ISO 21049: Plan 52, Plan 53A
  • Vessel can be dismantled: for optimum and simple cleaning of the vessel interior
  • Suitable for a wide range of operating conditions: TS5000 up to 30 bar / 200 °C
  • Sockets with recessed gasket: no contamination of the circuit by thread sealant
  • Vessel made of 1.4571 stainless steel / borosilicate sight-glasses: suitable for universal applications
  • PED 2014/68/EU (Design and production in accordance with EU Pressure Equipment Directive)
  • Chemical industry
  • Petrochemical industry
  • Oil and gas industry
  • Refining technology
The TS system performs all the basic functions of a buffer/barrier system for the operation of double seals:
  • to pressurize the buffer chamber
  • leakage compensation
  • buffer/barrier fluid is circulated by thermosiphon effect or forced circulation system
  • to cool the seal
  • to selectively absorb product leakage and prevent dry running (tandem arrangement)

Use compressed air or nitrogen for pressurization.
The modular system allows the TS5000 vessels to be combined with a wide range of system components such as, e.g. level switch, circulation pump, hand refill pump, thermometer, base frame, etc.