TS6000

TS6000 For a larger view, please mouseover the image.
For a larger view, please mouseover the image.
Thermosiphon system
(API Plan 52)


Item Description
1 Level switch
2 Manometer
3 Manifold
4 Pressure switch
5 Shut-off valve
6 Orifice

N1 to the mechanical seal
N2 from the mechanical seal
N3 Level switch
N4 Level switch
N5 Filling connection

Bottom
N6 Drain
N7 Cooling water IN
N8 Cooling water OUT

Cover
N9 Connection to flare

Dimensions for TS6002 / TS6003, values in brackets for TS6000 / TS6001
The EagleBurgmann Thermosiphon systems of the TS6000 range meet all the requirements to supply mechanical seals in accordance with the API 682 guidelines. The vessels are equipped with all essential connections for fitting additional components. The range is available in two standard vessel sizes (shown: TS6000) with dished heads; a version which can be dismantled is also available as an option. The modular system allows the TS6000 vessels to be combined with a wide range of system components such as, level switch/transmitter, pressure switch/transmitter, base frame, etc.

Circulation in accordance with API 682 / ISO 21049: Plan 52, Plan 53A
  • Operating limits up to 50 bar / 200°C: suitable for a wide range of demanding operating conditions
  • Robust design with weld-pad type sight-glass for optimum visual level monitoring
  • Modular system: combination with a wide range of system components possible
  • A version which can be dismantled is also available as an option: for optimum and simple cleaning of the vessel interior
  • PED 2014/68/EU (TS6001/TS6003: design and production in accordance with EU Pressure Equipment Directive)
  • ASME VIII, Div. 1 (TS6000/TS6002: design, calculation and production); U-stamp optional
  • API 682 3rd edition
  • API 682 4th edition
  • Refining technology
  • Oil and gas industry
  • Chemical industry
  • Petrochemical industry
The TS system performs all the basic functions of a buffer/barrier system for the operation of double seals:
  • to pressurize the buffer chamber
  • leakage compensation
  • buffer/barrier fluid is circulated by thermosiphon effect or forced circulation system
  • to cool the seal
  • to selectively absorb product leakage and prevent dry running (tandem arrangement)


Use compressed air or nitrogen for pressurization; pressurization is monitored by a pressure switch. The incorporated level switch issues a signal whenever the level of buffer/barrier fluid is too low.